ListenPoint Powered Room Module (2 M1 Max/ 60 Watts)
LPT-R12
Highlights
- Single point of contact for ceiling or wall speakers (60 Watts), expansion sensors, paging input and general purpose interface.
- Connects to the Control Unit via Cat-5e cable, making installation and maintenance simple.
- Bi-directional communication between M1 and room module provides excellent performance, coverage, features and reliability
Overview
The R12 ListenPoint Room Module (RM) is designed to easily mount on the ceiling or on the wall of a room and its primary purpose is to communicate with the ListenPoint Microphone/Media Interface (M1) via infrared light and provide power amplification (60 Watts) for the speakers mounted in the ceiling or on a wall. It connects to Control Unit with one (1) Cat-5e cable reducing cable clutter. The RM has a built in IR sensor/emitter that bi-directionally communicates with up to two (2) M1’s. Two (2) additional sensors may be added to the RM. The RM has a paging input and a general purpose interface for controlling or accepting control to/from other devices. The paintable surface (except the sensor lens) snaps into a supplied mounting platform and has a cable cover that hides the cables.Includes
Quick Reference Card
Architectural Specs
The room module shall connect to a control unit using a standard Cat-5e cable and shall provide bi-directional communication with infrared M1’s by means of an emitter-sensor built in to the room module. The room module shall accept up to two (2) M1’s simultaneously and the M1’s must be capable of auto-registering. The room module shall provide high resolution equalization for popular ceiling speaker models, and provide a seven band equalizer consisting of two tone controls and five bands of fully parametric equalization for room equalization. The room module shall provide 512 points of speaker equalization specific to certain speaker brands and five bands/two tone control room equalization. The room module shall be capable of adding two (2) additional IR sensors. The room module shall accept an external paging input that shall reduce the speaker level when paging audio is present. A general purpose interface shall provide an isolated input and a SPDT relay out that shall accept and deliver controls to external equipment. The room module shall snap into a mounting platform that can be mounted to wall board and ceiling tile and shall have a cable cover. The room module (except for the IR lens) shall be paintable. The LPT-R12 Room Module is specified.
CAD Drawing
Specifications
| Specifications | LPT-R12 | |
| Audio | Speaker Output | Four (4) amplifier channels w/ 2-pin euro connectors, each 4 Ohms @ 15 watts (60 watts total) |
| Paging Input | One (1) 2-pin Euro Connector, 8 ohm, 25 V, 70 V and 100 V - internally selectable | |
| 6 - 12 VDC Input | One (1) 2-pin Euro Connector, 600 Ohms | |
| Relay Output | One (1) 3-pin Euro Connector, Latching or Pulse Relay - programmed via software | |
| Microphone to Speaker Output Frequency Response | 200 Hz to 15 kHz, +/- 2 dB, < 2.0% THD, >75 dB SNR | |
| Input to Speaker Output Frequency Response | 20 Hz to 20 kHz, +/- 2 dB, < 0.1% THD, >75 dB SNR | |
| Speaker EQ | Quickfilter®, 512 points of equalization by speaker model | |
| Room EQ | Five (5) band parametric, Two (2) tone controls | |
| Infrared Emitter | 38 kHz subcarrier | |
| Infrared Sensor | 2.3 MHz, 2.8 MHz | |
| External Infrared Sensor | Two (2) phono connectors provided | |
| Controls and Indicators | Rear Panel | Four (4) 2-pin euro connectors, two Cat-5e w/ LED indicator connectors, two (2) phono connectors, |
| Power | Supplied via Control Unit | 19 VDC, 60 Watts via Cat-5e cable |
| Auxiliary Power Input | N/A | |
| Auxiliary Power Output | N/A | |
| Auxiliary Power Connector | N/A | |
| Auxiliary Power Supply Size | N/A | |
| Auxiliary Power Supply Line Cord | N/A | |
| Auxiliary Power Supply Line Cord Length | N/A | |
| Physical | Dimensions (H x W x D) | 2.1 x 8.5 x 6.9 in. (5.4 x 20.4 x 17.5 cm) |
| Mounting Platform Dimensions (H x W x D) | 2.5 x 8.5 x 9.8 in. (6.3 x 20.4 x 24.9 cm) | |
| Power Supply Dimensions (H x W x D) | 1.3 x 2.4 x 4.8 in. (34 x 60 x 122 cm) | |
| Room Module Mounting | Mounting platform provided, mounts to most electrical boxes. | |
| Cable Cover Mounting | Mounts to mounting platform. | |
| Weight | 1.75 lbs. (.8 kg) | |
| Shipping Weight | 3.0 lbs. (1.36 kg) | |
| Compliance | Room Module | CE, ROHS, FCC, Industry Canada |
| Power Supply | UL, CE, ROHS, FCC, Industry Canada | |
| Specifications are subject to change without notification | ||
Requirements
-
LPT-C2 ListenPoint Standard Control Unit
Select the ListenPoint LPT-C2 Control Unit for outstanding performance on a budget. Designed to blend into any room, the control unit can be wall, desk or rack mounted.
-
LPT-C6 ListenPoint Advanced Control Unit
Choose theListenPoint® LPT-C6 Control Unit for the ultimate in audio visual integration! 6 multimedia inputs - including pro audio inputs/outputs - USB for customization and direct teleconferencing/Skype™/VOIP port for bringing the outside world into the room.
Used With
-
LPT-C2 ListenPoint Standard Control Unit
Select the ListenPoint LPT-C2 Control Unit for outstanding performance on a budget. Designed to blend into any room, the control unit can be wall, desk or rack mounted.
-
LPT-C6 ListenPoint Advanced Control Unit
Choose theListenPoint® LPT-C6 Control Unit for the ultimate in audio visual integration! 6 multimedia inputs - including pro audio inputs/outputs - USB for customization and direct teleconferencing/Skype™/VOIP port for bringing the outside world into the room.
-
LPT-M1 ListenPoint Microphone/Media Interface Kit
User interface providing wireless connectivity for audio sources, a microphone and simple remote control.
Accessories
-
LA-70-P Cat-5e Plenum Cable (Per ft./ .3 m)
The LA-70-P cat-5e plenum cable is used to connect the ListenPoint Control Unit (CU) to the Room Module (RM).
-
LA-86-P RG-59 75 Ohm Plenum Coaxial Cable
The plenum coaxial cable is used to connect up to two expansion sensors to the ListenPoint room module (RM).
-
LA-393-P Cat-5e Preassembled Plenum Cable
The LA-393-P Cat-5e preassembled plenum cable is used to connect the ListenPoint Control Unit (CU) to the Room Module (RM).
-
LA-394-P 16 AWG Plenum Speaker Cable
The plenum speaker wire is used with the room module (RM) to connect speakers to the system.
-
LA-395-P RG-59 75 Ohm Preassembled Plenum Coaxial Cable
The plenum coaxial cable is used to connect up to two additional expansion sensors to the ListenPoint room module (RM).
-
LPT-A102 Replacement Mounting Platform for CU/RM
The replacement mounting platform is used with a control unit (CU) or room module (RM).
-
LPT-A103 Expansion Sensor for RM
The expansion sensor is used to expand the IR coverage within a room or area.
-
LPT-A104 6 in. (15 cm) Ceiling Speaker
The ceiling speaker offers an easy solution for mounting into acoustical tile or drop ceiling applications.
-
LPT-A106S 4 in. (10 cm) Wall Mount Speaker
The wall mount speaker offers an easy solution for mounting to any wall.
-
LPT-A108 Replacement Euro Connectors (6)
The replacement euro connectors are used with the control unit (CU) and room module (RM) when spare or new connectors are needed.
-
LPT-A109 RCA Connector for RG-59 Coaxial Cable
The RCA connector is used with the LA-395-P coaxial cable.
-
LPT-A117 Remote Power Supply Kit
The kit allows for the control unit (CU) and/or room module (RM) power supply to be installed in a remote location.
Support Documents
