ListenPoint High Powered Room Module (4 Mic Max/ 120 Watts)
LPT-R24
Highlights
- Single point of contact for ceiling or wall speakers (120 Watts), expansion sensors, paging input and general purpose interface.
- Connects to the Control Unit via Cat-5e cable, making installation simple by eliminating cable clutter.
- Bi-directional communication between microphone (4 Mic Max) and room module provides excellent performance, coverage, features and reliability.
- Microphones auto-register to the room module, making operation simple.
- Advanced Quickfilter provides 512 of equalization for precise tuning of pre loaded speaker models.
- Seven band DSP based equalizer – two tone controls and five fully parametric filters.
- Includes mounting platform for wallboard and drop ceilings and can be mounted directly to electrical boxes.
- Paintable surface (except the sensor lens) allows for customization to room aesthetic.
- Cable cover neatly conceals cabling.
- Speaker audio can be ducked (reduced in level) by external paging and/or the microphone can duck aux inputs.
- Optional addition of up to two (2) expansion sensors to provide additional room coverage.
Overview
The R24 ListenPoint Room Module (RM) is designed to easily mount on the ceiling or on the wall of a room and its primary purpose is to communicate with the M1 microphone via infrared light and provide power amplification (120 Watts) for the speakers mounted in the ceiling or on a wall. It connects to Control Unit with one (1) Cat-5e cable reducing cable clutter. The paintable surface (except the sensor lens) snaps into a supplied mounting platform and has a cable cover that hides the cables. The RM has a built in IR sensor/emitter that bi-directionally communicates with up to four (4) microphones. This unique feature auto-registers any microphone within the room for simple operation. Two (2) additional sensors may be added to the RM. The RM has a paging input and a general purpose interface for controlling or accepting control to/from other devices.Includes
Configurations
Architectural Specs
The room module shall connect to a control unit using a standard Cat-5e cable and shall provide bi-directional communication with infrared microphones by means of an emitter-sensor built in to the room module. The room module shall accept up to four (4) microphones simultaneously and the microphones must be capable of auto-registering. The room module shall provide high resolution equalization for popular ceiling speaker models, and provide a seven band equalizer consisting of two tone controls and five bands of fully parametric equalization for room equalization. The room module shall provide 512 points of speaker equalization specific to certain speaker brands and five bands/two tone control room equalization. The room module shall be capable of adding two (2) additional IR sensors. The room module shall accept an external paging input that shall reduce the speaker level when paging audio is present. A general purpose interface shall provide an isolated input and a SPDT relay out that shall accept and deliver controls to external equipment. The room module shall snap into a mounting platform that can be mounted to wall board and ceiling tile and shall have a cable cover. The room module (except for the IR lens) shall be paintable. The LPT-R24 Room Module is specified.
CAD Drawing
Specifications
| Specifications | LPT-R24 | |
| Audio | Speaker Output | Four (4) amplifier channel w/ 2-pin euro connectors, each 4 Ohms @ 30 watts (120 watts total) |
| Paging Input | One (1) 2-pin Euro Connector, 8 ohm, 25 V, 70 V and 100 V - internally selectable | |
| 6 - 12 VDC Input | One (1) 2-pin Euro Connector, 600 Ohms | |
| Relay Output | One (1) 3-pin Euro Connector, Latching or Pulse Relay - programmed via software | |
| Microphone to Speaker Output Frequency Response | 200 Hz to 15 kHz, +/- 2 dB, < 2.0% THD, >70 dB SNR | |
| Input to Speaker Output Frequency Response | 20 Hz to 20 kHz, +/- 2 dB, < 0.1% THD, >70 dB SNR | |
| Speaker EQ | Quickfilter®, 512 points of equalization by speaker model | |
| Room EQ | Five (5) band parametric, Two (2) tone controls | |
| Infrared Emitter | 38 kHz subcarrier | |
| Infrared Sensor | 2.3 MHz, 2.8 MHz, 3.2 MHz, 3.8 MHz | |
| External Infrared Sensor | Two (2) phono connectors provided | |
| Controls and Indicators | Rear Panel | Four (4) 2-pin euro connectors, two (2) Cat-5e w/ LED indicator connectors, two (2) phone connectors |
| Power | Supplied via Control Unit | 19 VDC, 60 watts via Cat-5e cable w/ additionaly auxiliary power supply (included) |
| Power Supply Input | 100-240 VAC, 50-60 Hz, 0.4 A | |
| Power Supply Output | 19 VDC, 3.2 A, 60.8 w | |
| Power Supply Connector | DC Plug type Connector, .2 in (5.5 mm) OD, center positive | |
| Power Supply Size | 1.3 x 2.4 x 4.8 in. (34 x 60 x 122 cm) | |
| Line Cord | Line cord is determined by each country's power configuration | |
| Line Cord Length | 6 ft. (1.8 m) | |
| Physical | Room Module Dimensions (H x W x D) | 2.1 x 8.5 x 6.9 in. (5.4 x 20.4 x 17.5 cm) |
| Room Module w/ Mounting Platform and Cable Cover Dimensions (H x W x D) | 2.5 x 8.5 x 9.8 in. (6.3 x 20.4 x 24.9 cm) | |
| Power Supply Dimensions (H x W x D) | 1.3 x 2.4 x 4.8 in. (34 x 60 x 122 cm) | |
| Room Module Mounting | Mounting platform provided, mounts to most electrical boxes. | |
| Cable Cover Mounting | Mounts to mounting platform. | |
| Room Module Weight | 1.75 lbs. (.8 kg) | |
| Shipping Weight | 3.0 lbs. (1.36 kg) | |
| Compliance | Room Module | CE, ROHS,FCC, Industry Canada |
| Power Supply | UL,CE, ROHS,FCC, Industry Canada | |
| Specifications are subject to change without notification | ||
Requirements
-
LPT-C6 ListenPoint Advanced Control Unit
The C6 ListenPoint Control Unit is an ideal unit for audio visual integration as it accommodates integration with teleconferencing devices bringing the outside world into the room.
-
LPT-C2 ListenPoint Standard Control Unit
The ListenPoint Control Unit is the heart of the ListenPoint system. It’s simple and easy for users with one, intuitive control for adjusting volume and selecting audio sources.
Used With
-
LPT-M1 ListenPoint Microphone Kit
The Microphone Kit provides exceptional audio quality, ease of use and years of dependable service. The intuitive design allows the user to control microphone volume/mute and auxiliary input volume.
Accessories
-
LA-394-P 16 AWG Plenum Speaker Cable
The plenum speaker wire is used with the room module (RM) to connect speakers to the system.
-
LA-395-P RG-59 75 Ohm Preassembled Plenum Coaxial Cable
The plenum cable is used to connect up to two expansion sensors to the ListenPoint room module (RM).
-
LPT-A103 Expansion Sensor for RM
The expansion sensor is used to expand the IR coverage within a room or area.
-
LPT-A104 6 in. (15 cm) Ceiling Speaker
The ceiling speaker offers an easy solution for mounting into acoustical tile or drop ceiling applications.
-
LPT-A104-P 6 in. (15 cm) Plenum Ceiling Speaker
The plenum ceiling speaker offers an easy solution for mounting into acoustical tile or drop ceiling applications.
-
LPT-A105 8 in. (20 cm) Ceiling Speaker
The ceiling speaker offers an easy solution for mounting into acoustical tile or drop ceiling applications.
-
LPT-A106 5 in. (13 cm) Wall Mount Speaker
The wall mount speaker offers an easy solution for mounting to any wall.
-
LPT-A109 RCA Connector for RG-59 Coaxial Cable
The RCA connector is used with the LA-395-P coaxial cable.
-
LPT-A113 Ceiling Tile Bridge
The ceiling tile bridge is a simple way to add extra support that may be needed for drop ceiling tile applications.